The ENVIDEST LT FC-2 series vacuum evaporator is designed to treat aqueous-based streams with a low contaminant load. The equipment operates with electrical energy and its heating and condensation system is based on a heat pump (HP) unit.
The forced circulation technology enables the treatment of slightly more scaling streams than those managed by heat pump evaporators with submerged heat exchangers. It stands out for its energy efficiency: as a double-effect system, it utilizes the latent heat of generated vapour in the first effect to heat the liquid in the second effect, thereby reducing the energy consumed.
The operation of the equipment is fully automatic - 24 hours a day.
Main features
- Technology: Heat Pump (Freon R-513A); Forced Circulation (FC)
- Single/Multi-Effect: Multi-effect
- Vacuum 1st/2nd Effect: ≈ 125/70 mbar
- Evaporation Temperature 1st/2nd Effect: ≈ 50/40 °C
- Evaporation Vessel: Vertical
- Droplet Separator: Inclined plate demister
- Heat Exchanger for Heating: Shell and tube
- Vacuum System: Venturi Ejector
- Control Unit*: PLC Siemens with HMI touch screen
- Protection: IP54
- Electricity Supply**: 400 V III + PE 50 Hz
- Standard Manufacturing Material: 1.4401/1.4404 (AISI 316/AISI 316L)
- Special Anti-corrosion Manufacturing Material***: 1.4410 (Superduplex 2507)
* Different PLC manufacturer available on request
** Different voltage supply available on request
*** Consult other available material options
Diagram

Technical specs
| Parameter | Unit | 6720 | 8400 | 12000 | 16800 | 20400 |
|---|---|---|---|---|---|---|
| Capacity* | L/day | 6720 | 8400 | 12000 | 16800 | 20400 |
| Electricity Consumption** | kWh/m³ | 110 | 110 | 110 | 110 | 110 |
| Length | mm | 3800 | 4000 | 4800 | 5200 | 5420 |
| Width | mm | 2400 | 2400 | 2400 | 2400 | 2400 |
| Height | mm | 2400 | 2490 | 2700 | 2800 | 2930 |
| Parameter | Unit | 26400 | 30000 | 33600 | 43200 | 52800 |
|---|---|---|---|---|---|---|
| Capacity* | L/day | 26400 | 30000 | 33600 | 43200 | 52800 |
| Electricity Consumption** | kWh/m³ | 110 | 110 | 110 | 110 | 110 |
| Length | mm | 5500 | 5500 | 6000 | 7000 | 7500 |
| Width | mm | 2200 | 2200 | 2500 | 2800 | 3200 |
| Height | mm | 3465 | 3500 | 3500 | 3700 | 5000 |
* Data refer to clean water when working continuously in standard conditions (T = 20 °C, P = 1013 mbar).
** Electricity consumption expressed in kWh per m3 of distillate produced.